Rheonics Thermal Control Module (TCM) Systems
Rheonics TCM is a line of devices that measure static viscosity and density of process fluid samples at configurable, controlled temperature setpoints, useful for laboratory and in-field mobile setups.
TCM Overview
Rheonics TCM is a line of devices that measure static viscosity and density of process fluid samples at configurable, controlled temperature setpoints, useful for laboratory and in-field mobile setups. One of their main benefits is the thermal uniformity that it achieves around the sensor probe, leading to high accuracy and precise viscosity and density measurements.
Compatible sensors:

SRV
Wide-range In-line Process Viscometer

SRD
In-line Process Density and Viscosity Meter

DVM
HPHT Density and Viscosity Sensor
Rheonics TCM Line

Tailored Thermal Modules
Pair with Type-SR or DVM probes for precise readings.

Controlled-Temperature Fluid Analysis
Measure viscosity and density at the temperature setpoints you define.

One Line, Four Ways to work on-line auto-sampling
Lab, inline, high-pressure, and field calibration setups.

STCM
Type-SR (SRV and SRD) Thermal Control Module
The STCM is designed for a lab environment, where the fluid properties of samples taken from the process are measured (viscosity and/or density). It controls the fluid’s temperature and maintains a thermally uniform environment around the sensor’s sensing element with the built-in heating and cooling module or through an external bath source.

STCM-IFP
Type-SR (SRV and SRD) Thermal Control Module - Inline Fluid Profiler
The STCM-IFP is the inline variant of the STCM. The STCM-IFP connects to the process through a bypass and automatically takes samples to measure the viscosity of the fluid with the Rheonics auto-sampling system at one or multiple temperatures.

DTCM
DVM Thermal Module
The DTCM is designed specifically to be used alongside the DVM sensor, enabling easy high-pressure, high-temperature laboratory setups, avoiding the use of large ovens. It controls the fluid’s temperature and maintains it thermally uniform around the sensor’s sensing element with the built-in heating and cooling module or through an external bath source.

Calibrator
Type-SR (SRV and SRD) Calibrator
The Rheonics Calibrator is used for field calibration, verifying the sensor probes’ operation, and making small adjustments to the measurement in case a drift has occurred. The calibrator allows to perform the frequently industry-required annual calibration on-site, reducing downtime.