Skip to content

Sensor Cable Comparison Table

Detailed comparison table of Rheonics sensor cables used on the sensor probe (SRV, SRD, DVP) offering Standard, High Temperature, and EX-certified options.

Cable Type
180° Standard cable
90° Standard cable
High-Temperature Cable
IP69K Sensor Cable
EX Sensor Cable
Preview
Connection Type
Straight
90° Angled
Straight
Straight
Circular Connector
Molded connector
M12
M12
M12
M12
M12
P/N
CABXX
CABXX-90
CABXX-HT
CABXX-69K
CABXX-EX
Insulation material - Sheath
PUR
PUR
PTFE
TPE-S
Special PVC for intrinsically safe installations
IP Rating
IP68
IP68
IP65
IP69K
IP67
Temperature range
-30°C to 90°C
-30°C to 90°C
150°C
105°C
-30°C to 80°C
Lenghts availables
5 m - 10 m - 30 m
Custom (up to 500 m/1500 feet)
5 m - 10 m - 30 m
Custom (up to 500 m/1500 feet)
5 m (15ft) only
5 m (15ft) only
5 m - 10 m - 30 m
Custom (max. 500 m/ 1500 ft)
Number of pins
8
8
8
8
8
Conductor cross-section
0.25 mm²
0.25 mm²
0.25 mm²
0.25 mm²
0.25 mm²
Link to Brochure
90° Angled Standard cable Datasheet
High-Temperature Cable Datasheet
IP69K Sensor Cable Datasheet
EX Sensor Cable Datasheet
QR code
Search

Rheonics at EXPOCOBRE 2026

Join Rheonics at EXPOCOBRE 2026 in Lima and explore how precision sensing is improving mining efficiency. From slurry density to chemical monitoring, see our technology in action.