If you are human, leave this field blank.SRV - Request for Quote FormConfigure SRVSelect the required options for the inline process viscometer SRV. Refer to the SRV-Datasheet for more information.(* indicates required)MaterialSensor probe wetted partSS: Stainless steel 316L (1.4435)C22: Hastelloy C22 (2.4602)Product Approvals (if required)EX-certified sensor required:Not requiredIECExATEXInstallation Location (for ATEX certified sensor)CountryUnited States (US)United Kingdom (UK)CanadaAustralia---AfghanistanÅland IslandsAlbaniaAlgeriaAndorraAngolaAnguillaAntarcticaAntigua and BarbudaArgentinaArmeniaArubaAmerican SamoaAustriaAzerbaijanBahamasBahrainBangladeshBarbadosBelarusBelgiumBelauBelizeBeninBermudaBhutanBoliviaBonaire, Saint Eustatius and SabaBosnia and HerzegovinaBotswanaBouvet IslandBrazilBritish Indian Ocean TerritoryBritish Virgin IslandsBruneiBulgariaBurkina FasoBurundiCambodiaCameroonCape VerdeCayman IslandsCentral African RepublicChadChileChinaChristmas IslandCocos (Keeling) IslandsColombiaComorosCongo (Brazzaville)Congo (Kinshasa)Cook IslandsCosta RicaCroatiaCubaCuraÇaoCyprusCzech RepublicDenmarkDjiboutiDominicaDominican RepublicEcuadorEgyptEl SalvadorEquatorial GuineaEritreaEstoniaEthiopiaFalkland IslandsFaroe IslandsFijiFinlandFranceFrench GuianaFrench PolynesiaFrench Southern TerritoriesGabonGambiaGeorgiaGermanyGhanaGibraltarGreeceGreenlandGrenadaGuadeloupeGuatemalaGuernseyGuineaGuinea-BissauGuyanaHaitiHeard Island and McDonald IslandsHondurasHong KongHungaryIcelandIndiaIndonesiaIranIraqRepublic of IrelandIsle of ManIsraelItalyIvory CoastJamaicaJapanJerseyJordanKazakhstanKenyaKiribatiKuwaitKyrgyzstanLaosLatviaLebanonLesothoLiberiaLibyaLiechtensteinLithuaniaLuxembourgMacao S.A.R., ChinaMacedoniaMadagascarMalawiMalaysiaMaldivesMaliMaltaMarshall IslandsMartiniqueMauritaniaMauritiusMayotteMexicoMicronesiaMoldovaMonacoMongoliaMontenegroMontserratMoroccoMozambiqueMyanmarNamibiaNauruNepalNetherlandsNetherlands AntillesNew CaledoniaNew ZealandNicaraguaNigerNigeriaNiueNorfolk IslandNorth KoreaNorwayOmanPakistanPalestinian TerritoryPanamaPapua New GuineaParaguayPeruPhilippinesPitcairnPolandPortugalQatarReunionRomaniaRussiaRwandaSaint BarthélemySaint HelenaSaint Kitts and NevisSaint LuciaSaint Martin (French part)Saint Martin (Dutch part)Saint Pierre and MiquelonSaint Vincent and the GrenadinesSan MarinoSão Tomé and PríncipeSaudi ArabiaSenegalSerbiaSeychellesSierra LeoneSingaporeSlovakiaSloveniaSolomon IslandsSomaliaSouth AfricaSouth Georgia/Sandwich IslandsSouth KoreaSouth SudanSpainSri LankaSudanSurinameSvalbard and Jan MayenSwazilandSwedenSwitzerlandSyriaTaiwanTajikistanTanzaniaThailandTimor-LesteTogoTokelauTongaTrinidad and TobagoTunisiaTurkeyTurkmenistanTurks and Caicos IslandsTuvaluUgandaUkraineUnited Arab EmiratesUruguayUzbekistanVanuatuVaticanVenezuelaVietnamWallis and FutunaWestern SaharaWestern SamoaYemenZambiaZimbabweLanguage (for ATEX requirements) Please state language in which you would like to receive the DoC (Declaration of Compliance) and Safety Information. Do you need a Hygienic Certification?-HS Probe VariantNone3A: 3-AEG: EHEDGSensor OptionsViscosity Range (select one) *V1 : 3 - 3000 cP : Standard viscosity rangeV2 : 3 - 50,000 cP : Extended viscosity rangeV3 : 0.5 - 3000 cP : Extended lower viscosity rangeV4 : custom : Customer specified viscosity rangeIf you selected V4 above, specify the viscosity range for your process fluid : Calibration (select one) *STD : Standard calibration accuracyCUS : Customer specified calibration accuracy - specify viscosity setpoints in input box belowIf selected CUS above, please specify the viscosity setpoints and accuracy requiredElectronics (select one) *Please refer to the Electronics and Communications Page for more information.E1 : SME-TRD : Transmitter housing with displayE2 : SME-TR : Transmitter housing with solid coverE3 : SME-DRM : DIN-rail mount housingFT Option - Fixed Transmitter SensorCommunicationRheonics electronics are pre-configured with the following communication options.C1 : 4-20 mA : 3 channels of 4-20 mA analog signalC2 : Modbus RTU (RS-485) : Modbus RTU over RS-485C3 : USB : USB 2.0 compliant service and data acquisition portC4 : Ethernet : Ethernet active on RJ45 connectorAdditional FieldBus Communication OptionsC5 : Bluetooth LE 4.0 : Bluetooth module for short range communication (only for E1)C6 : Modbus TCP (Article)C7 : Ethernet/IP (Article)C8 : HART (Article)C9 : Profinet (Article)Temperature (select one) *Note: With EX-SRV, the T4 option below is not available and T3 is only up to 185°CT1 : 125 °C : Sensor rated for operation in process fluids up to 125 °C (250 °F)T2 : 150 °C : Sensor rated for operation in process fluids up to 150 °C (300 °F)T3 : 200 °C : Sensor rated for operation in process fluids up to 200 °C (400 °F)T4 : >200 °C : Sensor rated for operation in process fluids above 200 °C (400 °F)If you selected T4 above, please specify the maximum working temperature : Pressure (select one) *Note: For X5 long insertion sensor probes, maximum pressure rating is 100 bar (1500 psi).P1 : 15 bar (200 psi) : Sensor rated for process fluids pressure up to 15 bar (200 psi)P2 : 70 bar (1000 psi) : Sensor rated for process fluids pressure up to 70 bar (1000 psi)P3 : 200 bar (3000 psi) : Sensor rated for process fluids pressure up to 200 bar (3000 psi)P4 : 350 bar (5000 psi) : Sensor rated for process fluids pressure up to 350 bar (5000 psi)P5 : 500 bar (7500 psi) : Sensor rated for process fluids pressure up to 500 bar (7500 psi)Process Connection (Select one) *X1 : 3/4" NPT threaded probe (Article)X1 : G 1/2" BSPP threaded probe (Article)X2 : Probe with Flange, specify flange DN/PN in box below (Article)X3 : Probe with Tri-Clamp, specify TC norm & size in box below (Article)X4 : Flush probe, specify flange type, norm & size in box below (Article)X5 : Long insertion probe (FPC), select A & B in sections below (Article)X6 : Slimline probe (SLP), select A & B in sections below (Drawing)X7 : Reactor probe (RP), select L & B in sections below (Drawing)X8 : Teletube probe (TT), select A & B in sections below (Article)For X2, X3, X4: Specify type, norm and size of process connection : For X5, X6, X7 and X8: Use the following fields to specify further configuration A: Insertion Length - For X5, X6 and X8, input insertion length of probe, A (in mm) in box below. Specify unit if other than mm.L: Total Probe Length - For X7RP150 - 150 mm [~6"] probe lengthRP250 - 250 mm [~10"] probe lengthRP350 - 350 mm [~14"] probe lengthRP450 - 450 mm [~20"] probe lengthB: Process connection type, norm and size - For X5, X6, X7 and X8Configuration drawings of the X5 long insertion sensor probe with various process connections :Long insertion probe configuration drawings Flange (Drawing) DIN11851 (Drawing) Triclamp (Drawing) Threaded (Drawing) Varinline (Drawing) Sensor Cable (Select length) *5m (15 feet) Sensor cable : Cable for connecting sensor to transmitter (PUR sheaths)10m (30 feet) Sensor cable : Cable for connecting sensor to transmitter (PUR sheaths)30m (90 feet) Sensor cable : Cable for connecting sensor to transmitter (PUR sheaths)Custom length sensor cable : Cable for connecting sensor to transmitter (PUR sheaths)For custom cable length - specify length in meter or feet : M12 Connection TypeSee reference pictures for straight connection and 90° angled connectionStraight90° AngledSelect all accessories that are requiredPlease refer to Accessories Page for list of accessories and their details. Note: EZB-03X : For EX-SRV, Zener barriers are automatically added to order.IFC-34N-SRV: Inline adapter for 3/4" NPT sensor probeIFC-15T-34N-SRV: Inline adapter for 1.5" TriClamp sensor probeTMA-34N: Tank mount adapter for 3/4" NPT sensor probeHPT-12G: Hygienic inline flow cell for G1/2" sensor probeHPT-SRV: SRV HPHT Flow cell for 3/4" NPT sensor probeTMB-TRX: Transmitter Mounting BracketTHX-SS: Stainless steel transmitter housing - additional surchargeWOL-34NS: 3/4" NPT sensor weldolet for 2" pipesWOL-34NL: 3/4" NPT sensor weldolet for pipes bigger than 2" or tanksHAW-12G-MTK: G1/2" Hygienic weldolet with metal seal for thick wallsHAW-12G-OTK: G1/2" Hygienic weldolet with O-ring seal for thick wallsHAW-12G-MTN: G1/2" Hygienic weldolet with metal seal for thin wallsHAW-12G-OTN: G1/2" Hygienic weldolet with O-ring seal for thin wallsSCC-SRX: Calibration cylinderSCS-00A: Calibration standSPS-SRX: Protective sleeve for SRV/SRDIMS-SR: Impact shield for sensor probeSTCM-STD: SRV thermal control moduleFET-15T-15T: Tri-Clamp flow elbow teeFTP-15T-XXX: Tri-Clamp spool pieceApplications & IndustriesSelect the applicable industry/industries, where you are looking to use the sensor. *Printing and CoatingIndustrial Mixing And GrindingFood And BeveragesEnergy And HydrocarbonsPetrochemicalsChemicalAutomotivePaper And PackagingLife Sciences And MedicalPumping And PipelineMarineMining, Minerals And MetalsOthers What is your application? Provide a brief introduction to your process. *Explore how these sensors are used by other customers for your application in our knowledge baseOrdering InformationQuantity required *Additional Comments/MessageBrief description about the application, any other requirements specific to the quoteRequested Date of DeliveryContact InformationName of contact person *Name of company *Type of company/organization *Please select the option which best describes your company/organizationEnd CustomerMachine ManufacturerSystem IntegratorResearch Organization/EducationDistributorProcurement companyOthersE-mail *Address *CountryUnited States (US)United Kingdom (UK)CanadaAustralia---AfghanistanÅland IslandsAlbaniaAlgeriaAndorraAngolaAnguillaAntarcticaAntigua and BarbudaArgentinaArmeniaArubaAmerican SamoaAustriaAzerbaijanBahamasBahrainBangladeshBarbadosBelarusBelgiumBelauBelizeBeninBermudaBhutanBoliviaBonaire, Saint Eustatius and SabaBosnia and HerzegovinaBotswanaBouvet IslandBrazilBritish Indian Ocean TerritoryBritish Virgin IslandsBruneiBulgariaBurkina FasoBurundiCambodiaCameroonCape VerdeCayman IslandsCentral African RepublicChadChileChinaChristmas IslandCocos (Keeling) IslandsColombiaComorosCongo (Brazzaville)Congo (Kinshasa)Cook IslandsCosta RicaCroatiaCubaCuraÇaoCyprusCzech RepublicDenmarkDjiboutiDominicaDominican RepublicEcuadorEgyptEl SalvadorEquatorial GuineaEritreaEstoniaEthiopiaFalkland IslandsFaroe IslandsFijiFinlandFranceFrench GuianaFrench PolynesiaFrench Southern TerritoriesGabonGambiaGeorgiaGermanyGhanaGibraltarGreeceGreenlandGrenadaGuadeloupeGuatemalaGuernseyGuineaGuinea-BissauGuyanaHaitiHeard Island and McDonald IslandsHondurasHong KongHungaryIcelandIndiaIndonesiaIranIraqRepublic of IrelandIsle of ManIsraelItalyIvory CoastJamaicaJapanJerseyJordanKazakhstanKenyaKiribatiKuwaitKyrgyzstanLaosLatviaLebanonLesothoLiberiaLibyaLiechtensteinLithuaniaLuxembourgMacao S.A.R., ChinaMacedoniaMadagascarMalawiMalaysiaMaldivesMaliMaltaMarshall IslandsMartiniqueMauritaniaMauritiusMayotteMexicoMicronesiaMoldovaMonacoMongoliaMontenegroMontserratMoroccoMozambiqueMyanmarNamibiaNauruNepalNetherlandsNetherlands AntillesNew CaledoniaNew ZealandNicaraguaNigerNigeriaNiueNorfolk IslandNorth KoreaNorwayOmanPakistanPalestinian TerritoryPanamaPapua New GuineaParaguayPeruPhilippinesPitcairnPolandPortugalQatarReunionRomaniaRussiaRwandaSaint BarthélemySaint HelenaSaint Kitts and NevisSaint LuciaSaint Martin (French part)Saint Martin (Dutch part)Saint Pierre and MiquelonSaint Vincent and the GrenadinesSan MarinoSão Tomé and PríncipeSaudi ArabiaSenegalSerbiaSeychellesSierra LeoneSingaporeSlovakiaSloveniaSolomon IslandsSomaliaSouth AfricaSouth Georgia/Sandwich IslandsSouth KoreaSouth SudanSpainSri LankaSudanSurinameSvalbard and Jan MayenSwazilandSwedenSwitzerlandSyriaTaiwanTajikistanTanzaniaThailandTimor-LesteTogoTokelauTongaTrinidad and TobagoTunisiaTurkeyTurkmenistanTurks and Caicos IslandsTuvaluUgandaUkraineUnited Arab EmiratesUruguayUzbekistanVanuatuVaticanVenezuelaVietnamWallis and FutunaWestern SaharaWestern SamoaYemenZambiaZimbabwePhone *Please provide your contact number.ExtensionCompany WebsitePrivacy NoticeBy clicking submit, you acknowledge that you have read the Privacy Notice.Sales Terms and ConditionsBy clicking submit, you agree to our Sales T&C.Captcha *reCAPTCHA is required.SubmitIf you are unable to submit this form, you can download the RFQ form as a pdf file. Select the options and fill the information requested and email to *protected email*Page Break